YSLY-JZ 300/500V Command cable

Uses

» Small diameter flexible cable for industrial use.

» Compatible for moderate mechanical loads, dry, humid, or wet areas.

» For use in machinery and production line construction, command, signaling, control, and measurement.

» For permanent and mobile installation, on the condition that heavy mechanical stress is not applied on the cable.

» Thanks to the cable’s small diameter and flexibility, it is compatible for use in narrow locations.

Technical Data and Conditions for Installation

» Work temperature: up to +70°C

» Bending radius: In a permanent installation, 6X the cable’s diameter and 15X the cable’s diameter in mobile applications.

» Maximum short circuit temperature for a 5-second duration is up to 150°C.”
 Work voltage 300/500V
 Testing voltage 2000V

» Compatible for indoor use, in dry, humid, or wet locations.

» Incompatible for indoor use, unless UV radiation protected and within the permitted range of temperatrures.

» The cable is not sensitive to random contact with fuel and oils, but not intended for constant submersion in them. 

The Cable’s Structure

» Conductor: Flexible Class 5 Copper

» Strand insulation: PVC

» Color coding: Black numbered strands. One of the strands is yellow/green

» The strands are twisted in concentric layers

» External sheathing: PVC

» Color: Gray

Compatible Cable Types

» Electrical power cable, command cable 